Red-lion PAX2A Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour ordinateurs Red-lion PAX2A. Red Lion PAX2A User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
3.80 (96.52)
(49.53)
(2.54)
(44.45)
3.60 (91.44)
4.14 (105)
1.95
0.10
1.75
1
3
2
4
UNIVERSAL PROCESS, VOLTAGE, CURRENT, RESISTANCE
AND TEMPERATURE INPUTS
UNIVERSAL AC/DC POWER SUPPLY
6 / 9 DIGIT DUAL LINE/TRI-COLOR DISPLAY WITH 0.71" & 0.35"
DIGITS
PROGRAMMABLE UNITS DISPLAY
VARIABLE CONTRAST AND INTENSITY DISPLAY
UP TO 160 SAMPLES PER SECOND CONVERSION RATE
BUILT-IN USB PROGRAMMING PORT ENABLING UNIT
CONFIGURATION WITH CRIMSON PROGRAMMING SOFTWARE
NEMA 4X/IP65 SEALED FRONT BEZEL
DESCRIPTION
The PAX2A Analog Panel Meter offers many features and performance
capabilities to suit a wide range of industrial applications. The PAX2A has a
universal input to handle various input signals including DC Voltage/Current,
Process, Resistance and Temperature. The optional plug-in output cards allow
the opportunity to configure the meter for present applications, while providing
easy upgrades for future needs. The PAX2A employs a dual line, tri-color
display with a large 0.71", tri-color 6 digit top display line and a 0.35", 9 digit
green bottom display line.
The meter provides a MAX and MIN reading memory with programmable
capture time. The capture time is used to prevent detection of false max or min
readings which may occur during start-up or unusual process events.
The signal totalizer (integrator) can be used to compute a time-input product.
This can be used to provide a readout of totalized flow or calculate service
intervals of motors, pumps, etc. The meter has up to four setpoint outputs,
implemented on plug-in option cards. The plug-in cards provide dual FORM-C
relays, quad FORM-A, or either quad sinking or quad sourcing open collector
logic outputs. The setpoint alarms can be configured to suit a variety of control
and alarm requirements.
Communication and bus capabilities are also available as option cards. These
include RS232, RS485, DeviceNet, and Profibus-DP. The PAX2A can be
programmed to utilize ModBus protocol. With ModBus, the user has access to
most configuration parameters. Readout values and setpoint alarm values can be
controlled through the bus. Additionally, the meter has a feature that allows a
remote computer to directly control the outputs of the meter.
The PAX2A includes a built-in USB programming port. With a Windows
®
based program, made available by Red Lion Controls, configuration data can be
downloaded to the PAX2A without the need of any additional option cards.
A linear DC output signal is available as an optional plug-in card. The card
provides either 20 mA or 10 V signals. The output can be scaled independent of
the input range and can track either the input, totalizer, max or min readings.
The meter has been specifically designed for harsh industrial environments.
With NEMA 4X/IP65 sealed bezel and extensive testing of noise effects and CE
requirements, the meter provides a tough reliable application solution.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in this
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired. Do not use this unit to directly
command motors, valves, or other actuators not equipped with safeguards. To do
so can be potentially harmful to persons or equipment in the event of a fault to
the unit.
MODEL PAX2A – 1/8 DIN ANALOG PANEL METER
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for
mounting clip installation is 2.1" (53.4) H x 5.5" (140) W.
PANEL CUT-OUT
Bulletin No. PAX2A-C
Drawing No. LP0830
Released 04/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
C
US LISTED
U
L
R
3RSD
PROCESS CONTROL EQUIPMENT
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - DIMENSIONS In inches (mm)

13.80 (96.52)(49.53)(2.54)(44.45)3.60 (91.44)4.14 (105)1.950.101.751324 UNIVERSAL PROCESS, VOLTAGE, CURRENT, RESISTANCE AND TEMPERATURE INPUTS UNI

Page 2 - Ordering infOrmaTiOn

10paX2a display lOOps ProNO Pro1-INPUt Pro2-FUNCt Pro 3-dISPLY Pro4-SCNdrY Pro5-totAL Pro6-SEtPNt Pro7-SErIAL Pro8-AnLOut Pro9-FACtrY PCOdE

Page 3 - Thermocouple Inputs:

11 321.0rEL NOGAL 321.0S3 500.0GAL 321.054 1000.0GAL ProNO DDDDPP 321.0S1 100.0GAL 321.0S2 100.0GALP 321.0COdE 0GALPPP hidE hidE M

Page 4 - LO/SINK HI/SOURCE

12ProNO Pro1-INPUt PrAN9E200U INPInput RangerAtE5 INPADC Rateround0.01 INPDisplayRoundingdECPNt0.00 INPDisplayDecimalPointOFFSEt0.00INPDisplayOffsetV

Page 5 - OpTiOnal plug-in OuTpuT Cards

13that the 2 scaling points be at opposite ends of the input signal being applied. The points do not have to be the signal limits. Display scaling wil

Page 6 - 2.0 seTTing The Jumpers

14PROGRAMMING MODE LOCK-OUTProgramming Mode is locked-out, as long as activated (maintained action). A security code can be configured to allow progra

Page 7 - 4.0 Wiring The meTer

15RESET MINIMUM DISPLAYWhen activated (momentary action), rESEt flashes and the Minimum resets to the present Input Display value. The Minimum functio

Page 8 - 4.1 POWER WIRING

16 ProNO Pro3-dISPLY PColorGrEEN Ln1DisplayColord-LEV4dSPDisplayIntensityLINE 1INPUt dSPLine 1Displayd-Cont7dSPDisplayContrastUNItSOFF dSPUnitsMn

Page 9 - Setpoint Annunciators

17LINE 2 MAX ACCESSLOC d-rEd d-ENtWhen configured for d-ENt, the Max Display value can be reset using a front keypad sequence. To reset, push the P ke

Page 10 - Programming

18 ProNO Pro4-SCNdrY PHI-AS rELSECHI-t1.0SECLO-AS rELSECLO-t1.0SECdSP-t2 SECMAX CaptureAssignmentMAX CaptureTimeMIN CaptureAssignmentMIN CaptureTime

Page 11 - 6.0 prOgramming The paX2a

19ProNOPro5-totAL PdECPNt0.000tOtt bASEMIN tOtSCLFAC1.000tOtLo Cut-19999.9tOtPWrUPNO tOtDecimalPointTime Base Scale Factor Low CutValuePower UpReset

Page 12 - DIGITAL FILTERING

2Ordering Information ...2General Meter Specifications ...3Optional Plug-In Cards ...5Installing the Meter

Page 13 - PARAMETER MENU

20 ProNO Pro6-SEtPNt PSELECtNO SPtSetpointSelectACtIONNO SnSetpointOutputActionASSIGNNONE SnSetpointAssignmentSEtPNt100SnSetpointValueBand/Deviat

Page 14

21SETPOINT VALUE-199999 to 999999Enter desired setpoint alarm value. Setpoint values can also be entered in the Display Mode during Program Lockout wh

Page 15

22ProNO Pro7-SErIAL PUSbCONFIG SRLUSBSetuptYPEMbASC CommsTypedAtA8 SRLData BitbAUd38400 SRLBaud RatePArItYNO SRLParity Bit MeterAddressAddr247SRLdELA

Page 16

23USBThe USB programming port is primarily intended to be used to configure the PAX2A with the Crimson programming software. It can also, be used as a

Page 17

24REGISTER ADDRESSREGISTER NAME LOW LIMIT HIGH LIMITFACTORY SETTINGACCESS COMMENTSFREQUENTLY USED REGISTERS40001 Input Relative Value (Hi word)N/A N/A

Page 18

25REGISTER ADDRESSREGISTER NAME LOW LIMIT HIGH LIMITFACTORY SETTINGACCESS COMMENTS40105 40205 Scaling Pt.1 Display Value (Hi word)-199999 999999 0 Rea

Page 19

26REGISTER ADDRESSREGISTER NAME LOW LIMIT HIGH LIMITFACTORY SETTINGACCESS COMMENTS40348 Line 2 Setpoint 3 Value Access 0 5 0 Read/Write 0=LOC, 1=d-rEd

Page 20

27REGISTER ADDRESSREGISTER NAME LOW LIMIT HIGH LIMITFACTORY SETTINGACCESS COMMENTS40428 Standby Operation 0 1 0 Read/Write 0 = No, 1 = Yes40429 Annunc

Page 21

28SERIAL RLC PROTOCOL COMMUNICATIONSRLC Communications requires the Serial Communications Type Parameter (tYPE) be set to “rLC”.SENDING SERIAL COMMAND

Page 22

29RECEIVING DATA FROM THE METERData is transmitted by the meter in response to either a transmit command (T), a print block command (P) or User Functi

Page 23 - SUPPORTED EXCEPTION CODES

3general meTer speCifiCaTiOns1. DISPLAY: Negative image LCDTop Line - 6 digit, 0.71" (18 mm), with tri-color backlight (red, green or orange), di

Page 24 - PAX2A MODBUS REGISTER TABLE

30COMMUNICATION FORMATData is transferred from the meter through a serial communication channel. In serial communications, the voltage is switched bet

Page 25

31Pro9-FACtrY PCOdE50FCSProNO FactoryService CodemOdule 9 - faCTOry serviCe OperaTiOns (9-FACtrY)PARAMETER MENURESTORE FACTORY DEFAULTSUse the ! and @

Page 26

32Preparation for Current, Volt, and Ohm Input Calibration Warning: Input Calibration of this meter requires a signal source capable of producing a

Page 27

33TROUBLESHOOTINGPROBLEM REMEDIESNo Display At Power-Up Check power level and power connectionsNo Display After Power-UpCheck Module 3: d-LEU, d-Cont,

Page 28 - OFS T, V

342-FUNCt USER INPUT/FUNCTION KEY PARAMETERSDISPLAY PARAMETER USER SETTINGUSrACtUSER ACTIVE STATEUSEr-1USER INPUT 1USEr-2USER INPUT 2F1FUNCTION KEY

Page 29

35 Pro8-AnLOut PtYPE4-20 AnLASSIGNNONE AnLANALOG0.000LOANALOG100.00HIUPdAtE0.0AnLbrnActLo AnLAnalog Type Analog OutputAssignmentAnalog LowScale Valu

Page 30 - Timing Diagrams

Red Lion ControlsHeadquarters20 Willow Springs CircleYork PA 17406Tel +1 (717) 767-6511Fax +1 (717) 764-0839Red Lion ControlsChinaUnit 101, XinAn Plaz

Page 31 - Service Code

4 9. EXCITATION POWER: Jumper selectableTransmitter Power: +18 VDC, ± 5% @ 50 mA max.Reference Voltage: + 2 VDC, ± 2%Compliance: 1KW load min (2 mA ma

Page 32 - OFFSEt) is set to 0

5WARNING: Disconnect all power to the unit before installing plug-in cards.Adding Option CardsThe PAX2A meters can be fitted with up to three optional

Page 33 - TROUBLESHOOTING

61.0 insTalling The meTer2.0 seTTing The JumpersInstallation The PAX2A meets NEMA 4X/IP65 requirements when properly installed. The unit is intended

Page 34

7The plug-in cards are separately purchased optional cards that perform specific functions. These cards plug into the main circuit board of the meter.

Page 35 - Temperature Input Only

84.1 POWER WIRING12AC/DCAC/DC4.2 VOLTAGE/RESISTANCE/CURRENT INPUT SIGNAL WIRINGIMPORTANT: Before connecting signal wires, the Input Range Jumpers an

Page 36 - LIMITED WARRANTY

94.4 USER INPUT WIRINGIf not using User Inputs, then skip this section. Only the appropriate User Input terminal has to be wired.Sourcing Logic (USrA